DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC is stored when a short is detected in the inverter with converter assembly (generator inverter) or the hybrid vehicle transaxle assembly (generator (MG1)). The cause of this malfunction may be one of the following:
Internal inverter malfunctionDESCRIPTION
For a description of the inverter.
Click here
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
---|---|---|---|---|---|
P0A7A73 | Generator Inverter Actuator Stuck Closed |
Current flow to any phase of the generator (MG1) exceeds the threshold after the generator inverter is shut down due to a DTC indicating a generator inverter malfunction (overheating, overcurrent or circuit malfunction) being stored. (1 trip detection logic) |
| Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
The motor generator control ECU monitors the generator inverter electric current. If the current exceeds the threshold for a specified period of time, the motor generator control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P0A7A (INF P0A7A73): GFIV detection (Short circuit malfunction) |
Required sensors/components | Generator inverter |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A7A (INF P0A7A73) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
HINT:
[*1] to [*3]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here
CAUTION / NOTICE / HINT
CAUTION:
Click here
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a |
Without waiting for 10 minutes |
NOTICE:
Click here
PROCEDURE
1. | CHECK DTC OUTPUT (HYBRID CONTROL) |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result | Proceed to |
---|---|
P0A7A73 only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Malfunction Content |
Relevant DTC | |
---|---|---|
Insulation Malfunction |
P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | |
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | |
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
HINT:
(e) Turn the power switch off.
B |
![]() | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
|
2. |
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1)) |
Click here
NG | ![]() | GO TO STEP 4 |
|
3. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT | ![]() | GO TO STEP 13 |
4. |
CHECK MOTOR CABLE (FOR MG1) |
Click here
NG | ![]() |
GO TO STEP 7 |
|
5. |
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY |
Click here
|
6. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT | ![]() | GO TO STEP 13 |
7. |
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1)) |
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the motor cable from the hybrid vehicle transaxle assembly.
(c) Check the generator (MG1) for an interphase short using a milliohmmeter. (1) Using a milliohmmeter, measure the resistance according to the value(s) in the table below. HINT: If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle has been stopped. Standard Resistance:
HINT: To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
The calculation is based on the following:
|
|
(d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Tester Connection | Condition |
Specified Condition |
---|---|---|
W1-4 (W) - Body ground and shield ground |
Power switch off | 100 MΩ or higher |
W1-5 (U) - Body ground and shield ground |
Power switch off | 100 MΩ or higher |
W1-6 (V) - Body ground and shield ground |
Power switch off | 100 MΩ or higher |
(e) Connect the motor cable.
NG | ![]() |
GO TO STEP 10 |
|
8. |
REPLACE MOTOR CABLE |
Click here
|
9. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
NEXT | ![]() | GO TO STEP 13 |
10. |
REPLACE MOTOR CABLE |
Click here
|
11. |
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY |
Click here
|
12. |
REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Click here
|
13. |
CHECK DTC OUTPUT (HYBRID CONTROL) |
(a) Check the other DTCs that were output together with DTC P0A7A73.
Powertrain > Motor Generator > Trouble Codes
Relevant DTC | |
---|---|
P0A7A9E |
Generator Inverter Stuck On |
P1C5F19 | Generator Inverter Circuit Current Above Threshold |
NOTICE:
DTC P0A7A73 is stored after DTC P0A7A9E and/or P1C5F19 is stored. After troubleshooting and repairing the malfunction which caused DTC P0A7A73 to be stored, be sure to troubleshoot the other DTCs.
NEXT | ![]() | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Door / Hatch: Hood
Adjustment ADJUSTMENT CAUTION / NOTICE / HINT *a Centering Bolt *b Standard Bolt HINT: Centering bolts are used to install the hood hinges and hood lock. The hood and hood lock cannot be adjusted with the centering bolts installed. Substitute the centering bolts with standard bolts with washers when ...