DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that current does not flow as commanded due to a generator output circuit malfunction. The cause of this malfunction may be one of the following:
Internal inverter malfunctionDESCRIPTION
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
---|---|---|---|---|---|
P0A7A72 | Generator Inverter Actuator Stuck Open |
Malfunction is detected when offset component occurs in current flowing through generator with one phase open malfunction (1 trip detection logic) |
| Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
The motor generator control ECU monitors the generator. If the motor generator control ECU detects a malfunction of the generator, the ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs | P0A7A (INF:P0A7A72) : Generator Inverter Performance |
Required sensors/components | Generator Inverter |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A7A (INF P0A7A72) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
Click here
Click here
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
HINT:
WIRING DIAGRAM
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here
CAUTION / NOTICE / HINT
CAUTION:
Click here
*a |
Without waiting for 10 minutes |
HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here
PROCEDURE
1. |
CHECK DTC OUTPUT |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble Codes
Result | Proceed to |
---|---|
P0A7A72 only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Insulation Malfunction |
Hybrid control system | P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
System Main Relay or High Voltage Circuit Malfunction |
Hybrid control system | P0AD911 |
Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
P1C8449 | High Voltage Power Resource Circuit Short during Ready ON |
Malfunction Content | System |
Relevant DTC | |
---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 | Generator Control Module Watchdog / Safety ОјC Failure |
P0A1A49 | Generator Control Module Internal Electronic Failure | ||
P0A1B1F | Generator Control Module Circuit Intermittent | ||
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
Hybrid control system | P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure | |
Power source circuit malfunction |
Motor generator control system | P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
Sensor and actuator circuit malfunction |
Motor generator control system |
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
Hybrid control system | P0C7600 |
Hybrid/EV Battery System Discharge Time Too Long | |
P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure |
HINT:
(e) Turn the power switch off.
B |
![]() | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
C |
![]() | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
2. |
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
---|---|
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
B |
![]() | CONNECT SECURELY |
C |
![]() | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
3. |
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT |
Click here
HINT:
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
NEXT | ![]() | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Can Communication System(for Hv Model): DCM Communication Stop Mode. Diagnosis System. Diagnostic Trouble Code Chart
DCM Communication Stop Mode DESCRIPTION Detection Item Symptom Trouble Area DCM Communication Stop Mode Any of the following conditions are met: Communication stop for "DCM" is indicated on the "Communication Bus Check" screen of the Techstream. Click here Communication stop history for "DCM" is ind ...