DIAGNOSTIC TROUBLE CODE CHART
Motor Generator Control System|
DTC No. | Detection Item |
MIL | Warning Indicate |
Link |
|---|---|---|---|---|
| P033500 |
Crankshaft Position Sensor "A" |
Does not come on | Master Warning Light: Comes on |
|
|
P033531 | Crankshaft Position Sensor "A" No Signal |
Does not come on | Master Warning Light: Comes on |
|
|
P034000 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |
Does not come on | Master Warning Light: Comes on |
|
|
P034031 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
Does not come on | Master Warning Light: Comes on |
|
|
P062F44 | Internal Control Module EEPROM Data Memory Failure |
Comes on | Master Warning Light: Does not come on |
|
|
P062F46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
Comes on | Master Warning Light: Comes on |
|
|
P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0A0011 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0A0015 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0A001C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0A0812 | DC/DC Converter Status Circuit Short to Battery |
Does not come on | Master Warning Light: Comes on |
|
|
P0A0814 | DC/DC Converter Status Circuit Short to Ground or Open |
Does not come on | Master Warning Light: Comes on |
|
|
P0A1112 | DC/DC Converter Enable Circuit Short to Battery |
Does not come on | Master Warning Light: Comes on |
|
|
P0A1114 | DC/DC Converter Enable Circuit Short to Ground or Open |
Does not come on | Master Warning Light: Comes on |
|
|
P0A1A47 | Generator Control Module Watchdog / Safety ОјC Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0A1A49 | Generator Control Module Internal Electronic Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0A1B1F | Generator Control Module Circuit Intermittent |
Comes on | Master Warning Light: Comes on |
|
|
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0A3F1F | Drive Motor "A" Position Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
Comes on | Master Warning Light: Comes on |
|
|
P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
Comes on | Master Warning Light: Comes on |
|
|
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0A4B1F | Generator Position Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum |
Comes on | Master Warning Light: Comes on |
|
|
P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum |
Comes on | Master Warning Light: |
|
|
P0A6012 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning Light: Comes on |
|
|
P0A6014 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning Light: Comes on |
|
|
P0A601C | Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning Light: Comes on |
|
|
P0A601F | Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0A6312 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
Does not come on | Master Warning Light: Comes on |
|
|
P0A6314 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
Does not come on | Master Warning Light: Comes on |
|
|
P0A631C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
Does not come on | Master Warning Light: Comes on |
|
|
P0A631F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0A7872 | Drive Motor "A" Inverter Actuator Stuck Open |
Comes on | Master Warning Light: Comes on |
|
|
P0A7873 | Drive Motor "A" Inverter Actuator Stuck Closed |
Comes on | Master Warning Light: Comes on |
|
|
P0A789E | Drive Motor "A" Inverter Stuck On |
Comes on | Master Warning Light: Comes on |
|
|
P0A7A72 | Generator Inverter Actuator Stuck Open |
Comes on | Master Warning Light: Comes on |
|
|
P0A7A73 | Generator Inverter Actuator Stuck Closed |
Comes on | Master Warning Light: Comes on |
|
|
P0A7A9E | Generator Inverter Stuck On |
Comes on | Master Warning Light: Comes on |
|
|
P0A9000 | Drive Motor "A" Performance |
Comes on | Master Warning Light: Comes on |
|
|
P0A9200 | Hybrid Generator Performance |
Comes on | Master Warning Light: Comes on |
|
|
P0A949E | DC/DC Converter Stuck On |
Comes on | Master Warning Light: Comes on |
|
|
P0AED11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0AED15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0AED1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0BE51F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0BE91F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0BED1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0BFF1D | Drive Motor "A" Circuit Current Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0C1900 | Drive Motor "A" Execution Torque Performance |
Comes on | Master Warning Light: Comes on |
|
|
P0C3811 | DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0C3815 | DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C381C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0C3D11 | DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0C3D15 | DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C3D1C | DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C501F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C5A1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0C6413 | Generator Position Sensor Circuit "A" Circuit Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C641F | Generator Position Sensor Circuit "A" Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0C6913 | Generator Position Sensor Circuit "B" Circuit Open |
Comes on | Master Warning Light: Comes on |
|
|
P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0C691F | Generator Position Sensor Circuit "B" Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0C7917 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0CA300 | DC/DC Converter Step Up Voltage Performance |
Comes on | Master Warning Light: Comes on |
|
|
P0D2D16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0D2D1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0D3319 | DC/DC Converter Circuit Current Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0E001F | Generator Phase U Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0E041F | Generator Phase V Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery |
Comes on | Master Warning Light: Comes on |
|
|
P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0E081F | Generator Phase W Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0E3116 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Below Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0E3117 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0E311F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0E511F | DC/DC Converter Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Comes on | Master Warning Light: Comes on |
|
|
P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range |
Comes on | Master Warning Light: Comes on |
|
|
P0E5717 | DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P0E5811 | DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
Comes on | Master Warning Light: Comes on |
|
|
P0E5815 | DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
Comes on | Master Warning Light: Comes on |
|
|
P0E581C | DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P0E7100 | Generator Execution Torque Performance |
Comes on | Master Warning Light: Comes on |
|
|
P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure |
Comes on | Master Warning Light: Comes on |
|
|
P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Comes on | Master Warning Light: Comes on |
|
|
P1C2E46 | Motor Generator ECU(EEPROM) Calibration / Parameter Memory Failure |
Does not come on | Master Warning Light: Comes on |
|
|
P1C5D19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P1C5F19 | Generator Inverter Circuit Current Above Threshold |
Comes on | Master Warning Light: Comes on |
|
|
P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1C621F | Generator Control Module Offset Power Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1C641F | Generator Control Module Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1C651F | Generator Control Module Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1C671F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P1CA51D | Hybrid Generator Circuit Current Out of Range |
Comes on | Master Warning Light: Comes on |
|
|
P1CAC49 | Generator Position Sensor Internal Electronic Failure |
Comes on | Master Warning Light: Comes on |
|
|
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
Comes on | Master Warning Light: Comes on |
|
|
P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
Comes on | Master Warning Light: Comes on |
|
|
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Comes on | Master Warning Light: Comes on |
|
|
P1CB59E | DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Comes on | Master Warning Light: Comes on |
|
|
P1CB69E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
Comes on | Master Warning Light: Comes on |
|
|
P1CCC96 | DC/DC Converter Enable Component Internal Failure |
Does not come on | Master Warning Light: Comes on |
|
|
P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
Comes on | Master Warning Light: Comes on |
|
|
P31241F | Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
Does not come on | Master Warning Light: Does not come on |
|
|
P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Comes on | Master Warning Light: Comes on |
|
|
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning Light: Comes on |
|
|
P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid |
Comes on | Master Warning Light: Comes on |
|
|
P313387 | Communication Error from Generator to Drive Motor "A" Missing Message |
Comes on | Master Warning Light: Comes on |
|
|
P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
Comes on | Master Warning Light: Comes on |
|
|
P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid |
Comes on | Master Warning Light: Comes on |
|
|
P313487 | Communication Error from Drive Motor "A" to Generator Missing Message |
Comes on | Master Warning Light: Comes on |
|
|
P314F1F | DC/DC Converter Voltage Sensor "A"(VL) Circuit Intermittent |
Comes on | Master Warning Light: Comes on |
|
|
P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range |
Does not come on | Master Warning Light: Comes on |
|
|
U010087 | Lost Communication With ECM/PCM "A" Missing Message |
Comes on | Master Warning Light: Comes on |
|
|
U029387 | Lost Communication With Hybrid Powertrain Control Module Missing Message |
Comes on | Master Warning Light: Comes on |
|
|
U117087 | Lost Communication With Brake System Control Module(ch2) Missing Message |
Comes on | Master Warning Light: Comes on |
|
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Can Communication System(for Hv Model): Headup Display Communication Stop Mode. How To Proceed With Troubleshooting. Hybrid Vehicle Control ECU Communication Stop Mode
Headup Display Communication Stop Mode DESCRIPTION Detection Item Symptom Trouble Area Headup Display Communication Stop Mode Any of the following conditions are met: Communication stop for "Head Up Display" is indicated on the "Communication Bus Check" screen of the Techstream. Click here Communica ...