Toyota Avalon (XX50): Relay

Inspection

INSPECTION

PROCEDURE

1. INSPECT ST RELAY

(a) Check the resistance.

(1) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

3 - 5

Battery voltage not applied to terminals 1 and 2

10 kΩ or higher

Battery voltage applied to terminals 1 and 2

Below 1 Ω

If the result is not as specified, replace the ST relay.

Engine Switch

Starter

See More:

Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Sfi System: Evaporative Emission System Incorrect Purge Flow Actuator Stuck On (P04417E,P04417F,P04419C)
DTC SUMMARY DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note P04417E Evaporative Emission System Incorrect Purge Flow Actuator Stuck On Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure is measured a ...