VEHICLE BEHAVIOR CHART
VEHICLE BEHAVIOR CHART
(a) Vehicle behavior categorized by DTC
If a DTC is output, the vehicle behaves as follows.
DTC No. | Detection Item |
Vehicle Behavior when DTC is Output |
---|---|---|
P033500 | Crankshaft Position Sensor "A" |
Normal driving |
P033531 | Crankshaft Position Sensor "A" No Signal |
Normal driving |
P034000 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor |
Normal driving |
P034031 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
Normal driving |
P062F44 | Internal Control Module EEPROM Data Memory Failure |
Normal driving |
P062F46 | Generator Control Module (EEPROM Learning Value) Calibration / Parameter Memory Failure |
Reduced output power |
P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
Hybrid system stopped |
P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
Hybrid system stopped |
P0A0011 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
Normal driving |
P0A0015 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
Normal driving |
P0A001C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
Normal driving |
P0A0812 | DC/DC Converter Status Circuit Short to Battery |
Normal driving |
P0A0814 | DC/DC Converter Status Circuit Short to Ground or Open |
Normal driving |
P0A1112 | DC/DC Converter Enable Circuit Short to Battery |
Normal driving |
P0A1114 | DC/DC Converter Enable Circuit Short to Ground or Open |
Normal driving |
P0A1A47 | Generator Control Module Watchdog / Safety μC Failure |
|
P0A1A49 |
Generator Control Module Internal Electronic Failure |
|
P0A1B1F |
Generator Control Module Circuit Intermittent |
Hybrid system stopped |
P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
|
P0A3F1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
- |
P0A3F21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
|
P0A3F22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
|
P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
|
P0A4B1F |
Generator Position Sensor Circuit Intermittent |
- |
P0A4B21 |
Generator Position Sensor Signal Amplitude < Minimum |
|
P0A4B22 |
Generator Position Sensor Signal Amplitude > Maximum |
|
P0A6012 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
Normal driving |
P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
Normal driving |
P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
Normal driving |
P0A601F | Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
- |
P0A6312 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
Normal driving |
P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
Normal driving |
P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
Normal driving |
P0A631F | Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
- |
P0A7872 |
Drive Motor "A" Inverter Actuator Stuck Open |
|
P0A7873 |
Drive Motor "A" Inverter Actuator Stuck Closed |
|
P0A789E |
Drive Motor "A" Inverter Stuck On |
|
P0A7A72 |
Generator Inverter Actuator Stuck Open |
|
P0A7A73 |
Generator Inverter Actuator Stuck Closed |
|
P0A7A9E |
Generator Inverter Stuck On |
|
P0A9000 |
Drive Motor "A" Performance |
|
P0A9200 |
Hybrid Generator Performance |
|
P0A949E |
DC/DC Converter Stuck On |
|
P0AED11 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Normal driving |
P0AED15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Normal driving |
P0AED1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
Normal driving |
P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
|
P0BE514 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
|
P0BE51F |
Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
- |
P0BE528 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0BE912 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
|
P0BE914 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
|
P0BE91F |
Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
- |
P0BE928 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0BED12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
|
P0BED14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
|
P0BED1F |
Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
- |
P0BED28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
|
P0BFF1D |
Drive Motor "A" Circuit Current Out of Range |
|
P0C1900 |
Drive Motor "A" Execution Torque Performance |
|
P0C3811 |
DC/DC Converter Temperature Sensor "A" Circuit Short to Ground |
Normal driving |
P0C3815 | DC/DC Converter Temperature Sensor "A" Circuit Short to Battery or Open |
Normal driving |
P0C381C | DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
Normal driving |
P0C3D11 | DC/DC Converter Temperature Sensor "B" Circuit Short to Ground |
Normal driving |
P0C3D15 | DC/DC Converter Temperature Sensor "B" Circuit Short to Battery or Open |
Normal driving |
P0C3D1C | DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
Normal driving |
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
|
P0C5016 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
|
P0C5017 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
|
P0C501F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
- |
P0C5A13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
|
P0C5A16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
|
P0C5A17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
|
P0C5A1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
- |
P0C6413 |
Generator Position Sensor Circuit "A" Circuit Open |
|
P0C6416 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
|
P0C6417 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
|
P0C641F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
- |
P0C6913 |
Generator Position Sensor Circuit "B" Circuit Open |
|
P0C6916 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
|
P0C6917 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
|
P0C691F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
- |
P0C7917 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
|
P0CA300 |
DC/DC Converter Step Up Voltage Performance |
|
P0D2D16 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
Reduced output power |
P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
Reduced output power |
P0D2D1F | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
- |
P0D3319 |
DC/DC Converter Circuit Current Above Threshold |
|
P0DFA62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
|
P0E0012 |
Generator Phase U Current Sensor Circuit Short to Battery |
|
P0E0014 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
|
P0E001F |
Generator Phase U Current Sensor Circuit Intermittent |
- |
P0E0028 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0E0412 |
Generator Phase V Current Sensor Circuit Short to Battery |
|
P0E0414 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
|
P0E041F |
Generator Phase V Current Sensor Circuit Intermittent |
- |
P0E0428 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0E0812 |
Generator Phase W Current Sensor Circuit Short to Battery |
|
P0E0814 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
|
P0E081F |
Generator Phase W Current Sensor Circuit Intermittent |
- |
P0E0828 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
|
P0E3116 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold |
Reduced output power |
P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
Reduced output power |
P0E311F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
- |
P0E5111 |
DC/DC Converter Current Sensor Circuit Short to Ground |
Reduced output power |
P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open |
Reduced output power |
P0E511F | DC/DC Converter Current Sensor Circuit Intermittent |
- |
P0E5128 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Reduced output power |
P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range |
Reduced output power |
P0E5717 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
|
P0E5811 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
Normal driving |
P0E5815 | DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
Normal driving |
P0E581C | DC/DC Converter Temperature Sensor 2 Circuit Voltage Out of Range |
Normal driving |
P0E7100 | Generator Execution Torque Performance |
|
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
|
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
|
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
Hybrid system stopped |
P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
Hybrid system stopped |
P1C2E46 | Motor Generator ECU (EEPROM) Calibration / Parameter Memory Failure |
- |
P1C5D19 |
Drive Motor "A" Inverter Circuit Current Above Threshold |
|
P1C5F19 |
Generator Inverter Circuit Current Above Threshold |
|
P1C601F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
- |
P1C621F |
Generator Control Module Offset Power Circuit Intermittent |
- |
P1C641F |
Generator Control Module Circuit Intermittent |
- |
P1C651F |
Generator Control Module Circuit Intermittent |
- |
P1C671F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
- |
P1C691F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
- |
P1CA51D |
Hybrid Generator Circuit Current Out of Range |
|
P1CAC49 |
Generator Position Sensor Internal Electronic Failure |
|
P1CAD49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
|
P1CAF38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
|
P1CB038 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
|
P1CB59E |
DC/DC Converter Voltage Sensor "A" (VL) Stuck On |
|
P1CB69E |
Drive Motor "A" Inverter Voltage Sensor (VH) Stuck On |
Reduced output power |
P1CCC96 | DC/DC Converter Enable Component Internal Failure |
Normal driving |
P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
Reduced output power |
P31241F | Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
- |
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid system stopped |
P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
|
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
|
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
|
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
|
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
|
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
|
P314F1F |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
Reduced output power |
P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range |
Hybrid system stopped |
U010087 | Lost Communication With ECM/PCM "A" Missing Message |
Normal driving |
U029387 | Lost Communication With Hybrid Powertrain Control Module Missing Message |
Normal driving |
U117087 | Lost Communication With Brake System Control Module (ch2) Missing Message |
Normal driving |
(b) Relationship between the above and the multi-information display
Multi-information Display |
Vehicle Behavior |
---|---|
Driving:
| Hybrid system stopped |
Driving:
|
|
Driving:
| A driving range is limited |
Reduced Output Power Visit Your Dealer |
Reduced output power |
Greatly Reduced Output Power Visit Your Dealer |
Greatly reduced output power |
Driving:
|
|
"â—‹": Varies depending on the remaining driving range.
Toyota Avalon (XX50) 2019-2022 Service & Repair Manual > Can Communication System(for Gasoline Model): Radio Receiver Assembly Communication Stop Mode. Rear Television Camera Communication Stop Mode. Restraints Occupant Classification System Module Communication Stop Mode
Radio Receiver Assembly Communication Stop Mode DESCRIPTION Detection Item Symptom Trouble Area Radio Receiver Assembly Communication Stop Mode Any of the following conditions are met: Communication stop for "Display and Navigation (AVN)" is indicated on the "Communication Bus Check" screen of the T ...