Toyota Avalon (XX50): Drive Motor "A" Position Sensor Internal Electronic Failure (P1CAD49,P1C651F,P1CB038). DC/DC Converter Voltage Sensor "A"(VL) Stuck On (P1CB59E). Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On (
Drive Motor "A" Position Sensor Internal Electronic Failure (P1CAD49,P1C651F,P1CB038)
DESCRIPTION
The motor
generator control ECU (MG ECU) , which is built into the inverter with
converter assembly, monitors its internal operation and detects
malfunctions.
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P1C651F | Generator Control Module Circuit Intermittent |
Excitation
signal (REF signal) for resolver angle detection cycle malfunction
detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
- Inverter with converter assembly
- Hybrid vehicle transaxle assembly
- Wire harness or connector
| Does not come on |
Master Warning Light: Does not come on |
P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
Motor resolver angle malfunction: The difference between the resolver angle for control and estimated resolver angle exceeds the allowable limit.
(1 trip detection logic) |
- Inverter with converter assembly
- Hybrid vehicle transaxle assembly
- Wire harness or connector
| Comes on |
Master Warning Light: Comes on |
P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
Resolver REF signal cycle malfunction: Excitation signal (REF signal) for resolver angle detection cycle malfunction
(1 trip detection logic) |
- Inverter with converter assembly
- Hybrid vehicle transaxle assembly
- Wire harness or connector
| Comes on |
Master Warning Light: Comes on |
HINT:
Although the DTC titles generator control module, these DTCs relate to the motor control module.
Related Data List
DTC No. | Data List |
P1CAD49 | Motor Revolution |
P1CB038 |
MONITOR DESCRIPTION
The
motor generator control ECU performs diagnostic tests to verify proper
operation of internal ECU systems. In one of those tests, the motor
generator control ECU checks for an R/D (Resolver/ Digital converter)
malfunction involving the motor resolver. If the motor generator control
ECU detects an R/D converter error, it will conclude that there is an
internal malfunction involving the motor resolver. The motor generator
control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P1CAD (INF P1CAD49): Drive Motor "A" Control Module R/D Processing (Drive Motor "A" Position) Performance
P1CB0 (INF P1CB038): Drive Motor "A" Position Sensor Reference Signal Performance |
Required sensors/components | Motor resolver |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | Immediately |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P1CAD (INF P1CAD49) is not detected
DTC P1CB0 (INF P1CB038) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more.* [*1]
*: Lightly wiggle the connectors and wire harnesses up and down and right and left.
- Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
- Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine. [*3]
- Keep the engine running for 5 seconds or more. [*4]
- Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more. [*5]
- Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more. [*6]
HINT:
[*1] to [*6]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for DTC P1CAC49.
Click here
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After
turning the power switch off, waiting time may be required before
disconnecting the cable from the negative (-) auxiliary battery
terminal. Therefore, make sure to read the disconnecting the cable from
the negative (-) auxiliary battery terminal notices before proceeding
with work.
Click here
HINT:
- If the problem symptom cannot be reproduced, performing a road test on a
road on which the vehicle tends to vibrate will make it easier to
reproduce the symptom.
- If the resolver is malfunctioning, the vehicle may not drive smoothly.
- When inspecting the connectors, if it is difficult to judge if a
connector was disconnected, deformed or improperly secured, disconnect
and reconnect the connector and then check for DTCs again. Check if the
same DTC is output. If the same DTC is not output, improper connection
of connectors is suspected.
- As a malfunction detection threshold may be exceeded when performing the
vibration or heat connector inspections, make sure to perform the
following inspection to check that the DTC was not stored due to the
malfunction of a part.
PROCEDURE
1. | CHECK DTC OUTPUT (MOTOR GENERATOR CONTROL) |
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Motor Generator > Trouble Codes
Result | Proceed to |
P1CAD49, P1CB038 or P1C651F only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Relevant DTC |
P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold |
P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
(e) Turn the power switch off.
B | |
GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
A |
| |
2. |
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
B |
| CONNECT SECURELY |
C |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
A |
| |
3. |
CHECK GENERATOR RESOLVER CIRCUIT |
Click here
NEXT |
| |
4. |
CHECK MOTOR RESOLVER CIRCUIT |
Click here
HINT:
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
NEXT |
| REPLACE INVERTER WITH CONVERTER ASSEMBLY |
DC/DC Converter Voltage Sensor "A"(VL) Stuck On (P1CB59E)
DTC SUMMARY
MALFUNCTION DESCRIPTION
If
an overvoltage malfunction occurs in the boost converter, the motor
generator control ECU (MG ECU) detects the malfunction and stores this
DTC. The cause of this malfunction may be one of the following:
Internal inverter malfunction
- Inverter with converter assembly internal circuit malfunction
- Malfunction in ECU that controls the inverter
DESCRIPTION
For a description of the boost converter.
Click here
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P1CB59E | DC/DC Converter Voltage Sensor "A"(VL) Stuck On |
Boost converter overvoltage signal detected (circuit malfunction):
A circuit malfunction is detected before boosting. (1 trip detection logic) |
- Wire harness or connector
- Inverter with converter assembly
| Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
If
the boost converter detects a circuit malfunction, it will transmit a
boost converter overvoltage signal to the motor generator control ECU.
Upon receiving this signal, the motor generator control ECU will
illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P0A94 (INF P1CB59E): OVH detection (Circuit malfunction) |
Required sensors/components | Boost converter |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A94 (INF P1CB59E) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With the power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After
turning the power switch off, waiting time may be required before
disconnecting the cable from the negative (-) auxiliary battery
terminal. Therefore, make sure to read the disconnecting the cable from
the negative (-) auxiliary battery terminal notices before proceeding
with work.
Click here
PROCEDURE
1. |
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
A |
| REPLACE INVERTER WITH CONVERTER ASSEMBLY |
B |
| CONNECT SECURELY |
C |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On (P1CB69E)
DTC SUMMARY
MALFUNCTION DESCRIPTION
If
an overvoltage malfunction occurs in the motor inverter and generator
inverter, the motor generator control ECU (MG ECU) detects the
malfunction and stores this DTC. The cause of this malfunction may be
one of the following:
Internal inverter malfunction
- Inverter with converter assembly internal circuit malfunction
- Malfunction in ECU that controls the inverter
DESCRIPTION
For a description of the inverter.
Click here
DTC No. | Detection Item |
DTC Detection Condition | Trouble Area |
MIL | Warning Indicate |
P1CB69E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
Motor inverter overvoltage signal detected (circuit malfunction)
(1 trip detection logic) |
- Inverter with converter assembly
- Wire harness or connector
| Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
If
the motor inverter detects a circuit malfunction, it will transmit a
motor inverter overvoltage signal to the motor generator control ECU.
Upon receiving this signal, the motor generator control ECU will
illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs | P0A78 (INF P1CB69E): OVH detection (Circuit malfunction) |
Required sensors/components | Motor inverter |
Frequency of operation | Continuous |
Duration | TMC's intellectual property |
MIL operation | 1 driving cycle |
Sequence of operation | None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property | - |
COMPONENT OPERATING RANGE
Motor generator control ECU | DTC P0A78 (INF P1CB69E) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the
vehicle has returned to normal by performing the following All Readiness
check procedure.
Click here
- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION / NOTICE / HINT
CAUTION:
NOTICE:
After
turning the power switch off, waiting time may be required before
disconnecting the cable from the negative (-) auxiliary battery
terminal. Therefore, make sure to read the disconnecting the cable from
the negative (-) auxiliary battery terminal notices before proceeding
with work.
Click here
PROCEDURE
1. |
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Click here
Result | Proceed to |
OK | A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
A |
| REPLACE INVERTER WITH CONVERTER ASSEMBLY |
B |
| CONNECT SECURELY |
C |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |